The 65083S precision load cell is engineered to excel in demanding environments often found in food and chemical processing. It is versatile, suitable for both single-cell and multiple-cell setups. The load cell features a threaded load hole, facilitating seamless integration with mounting hardware or leveling feet, commonly used with floor scales. Its capacity spans from 1,000 to 10,000 pounds and comes equipped with a 20-foot load cell cable for added convenience.
65083S Load Cell Specifications
Full Scale Output: 2.0 mV/V
Output Resistance: 349 to 355 ohm
Input Resistance: 343 to 357 ohm
Material/Finish: Stainless steel
Temperature: Compensated range 14 °F to 104 °F (-10 °C to 40 °C) Operating range 0 °F to 150 °F (-18 °C to 65 °C)
Seal Type: Welded-seal, IP67 Hermetically sealed, IP69KSafe Overload: 150% full scale
Safe Sideload: 100% full scale
Rated Excitation: 5 to 10 V DC (15 V maximum)
Combined Error: 0.02% full scale
Non-Repeatability: 0.01% full scale
Insulation Resistance: 5,000 megohm
Deflection at Capacity: 1,000 to 4,000 lb: 0.012 in 5,000 to 10,000 lb: 0.030 inCable Length: 20 ft
Cable Diameter: 0.220 in PTFE jacket
Conduit Adapter Size: IP67: 1/4-18 NPT IP69K: 1/2-14 NPT
Cable Color Code: Red +Excitation Black –Excitation Green +Signal White –Signal
Warranty: One-year limited
Approvals: cFMus NTEP