top of page

VPG Celtron DSR Alloy Steel, Double-Ended Beam Load Cell – Ricelake

A double-ended beam designed for center loading, specifically tailored for applications involving tanks, hoppers, and silos. The capacities of the beam range from 1,000 lb to 75,000 lb, and it comes equipped with 25 ft of load cell cable for comprehensive use.

DSR Load Cell Specifications

Full Scale Output: 3.0 mV/V

Output Resistance: 700 (± 5) ohm

Input Resistance: 770 (± 10) ohm

Material/Finish: High-alloy steel, nickel plated

Temperature: Operating range 0 °F to 150 °F (-18 °C to 65 °C)

Seal Type: Environmentally sealed, IP67

Safe Overload: 150% full scaleSafe Sideload: 100% full scale

Rated Excitation: 5 to 10 VDC (15 V maximum)

Nonlinearity: 0.03% full scale

Hysteresis: 0.02% full scale

Insulation Resistance: 5,000 megohm

Deflection at Capacity: 1,000 to 3,000 lb: 0.01 in 5,000 lb: 0.015 in 10,000 to 20,000 lb: 0.022 in 25,000 lb: 0.036 in 50,000 lb: 0.052 in 75,000 lb: 0.07 inCable Length: 25 ft

Cable Diameter: 1,000 to 25,000 lb: 0.200 in 50,000 to 75,000 lb: 0.305 in Polyurethane jacket

Cable Color Code: Red +Excitation Black –Excitation Green +Signal White –Signal

Warranty: One-year limited

Approvals: cFMus

4 views0 comments